Manometer

                MP 200  

 

       

 

   Technical data                         

Applications
For pressure, temperature, velocity, current/voltage, CO measurements
For pressure, temperature, velocity, current/voltage, CO measurements
For pressure, temperature, velocity, current/voltage, CO measurements
For pressure, temperature, velocity, current/voltage, CO measurements
Supplied withpressure measurement module, transport caseand calibration certificate.

Functions : Pressure, Velocity, Airflow, Temperature, current/voltage, Air quality(CO/temperature), Datalogger.
Connection :
Interchangeable measurement modules (current/voltage, thermocouple, pressure),
Wireless connection Intrument/Computer,
Smart-Plus system, probes automatically recognized when connected to the instrument.
Measuring range (see datasheet)

Measuring ranges

MANOMETER
Pressure
MP200 P : Pressure module 0-500 Pa Resolution 0.1 Pa
MP200 M : Pressure module 0-2500 Pa Resolution 1 Pa
MP200 G : Pressure module 0-10,000 Pa Resolution 1 Pa
MP200 H : Pressure module 0-500 mbar Resolution 1 mbar
MP200 HP : Pressure module 0-2000 mbar Resolution 1 mbar
Velocity
Pitot : 2 to 100 m/s Resolution 0,1 m/s
Debimo blades : 4 to 100 m/s Resolution 0,1 m/s
Airflow
Pitot : 0 to 99,999 m³/h Resolution 1 m³/h
Debimo blades : 0 to 99,999 m³/h Resolution 1 m³/h

TEMPERATURE
Thermocouple K : -200 to +1300°C Resolution 0,1°C
Thermocouple J : -100 to +750°C Resolution 0,1°C
Thermocouple T : -200 to +400°C Resolution 0,1°C

AIR QUALITY
CO / temperature probe
CO : from 0 to 1000 ppm Resolution 0,1 ppm from 0 to 100 ppm, 1 ppm beyond
Temperature : from -20°C to +80°C Resolution 0,1 °C

CURRENT / VOLTAGE
2,5 V Resolution 0,001V
from 0 to 0 V Resolution 0,01V
from 4/20 mA Resolution 0,01mA

Detailed functions

MICRO-MANOMETER
Pressure
: Automatic (MP200P) or manual self calibration (MP200 M, MP200 G), select units, pressure integration (0 to 9), point / point average, automatic point / point average, automatic average, hold, min/max values, standard deviation, storage.

Velocity : select Pitot tube or Debimo or coefficient for others sensing elements, select duct, select units, point / point average, automatic point / point average, automatic average, temperature balancing (manual and automatic), manual air pressure balancing, K2 factor, hold, min/max values, standard deviation, storage.

THERMOCOUPLE THERMOMETER
Select units, select thermocouple type, Delta T, hold, min/max values, storage.

CURRENT / VOLTAGE
Adjustable scales, hold, min/max values, storage.

SONDE CO / TEMPERATURE
Audible alarm(2 thresholds), hold, min/max values, storage

Measuring units
Pressure : Pa, mmH2O, mbar, hPa, In wg, mmHg, DaPa
Velocity : m/s, fpm, Km/h, mph
Airflow : m³/h, cfm, l/s, m³/s
Temperature : °C, °F
Current/voltage : V, mA
CO/temperature : ppm, °C or °F

  et Modules probes  

Sondes Smart +
Whole probes integrate the SMART PLUS System and are only compatibles with the Class 200 and 300 electronic portable devices. Exchangeable, they are adjusted individually or calibrated with the device and are automatically recognised when plug-in. These Probes are come with a calibration certificate (except Thermocouple K Probes)


Temperature Probe
Large choice oftemperature probe for all applications : general, penetration,contact, ambient, withlamella, velcro...
Type :Pt 100 / Pt 1000,NTC , Thermocouple

Wireless* model available
* Pt 100 probe only


CO (CO2) / Temp. / Hum. Probe
CO / Temperature probe
CO :from 0to 1000 ppm (electrochemical sensor)
Temperature :from -20to +80°C
CO2 / Temperature probe
CO2 :from 0to 5000 ppm (NDIR sensor)
Temperature :from -20to +80°C
CO2 / Temperature / Hygrometry probe
CO2 : from 0to 5000 ppm (NDIR sensor)
Temperature :from -20to +80°C
Relative humidity : 5to 95%RH

Interchangeable Measurement Modules
Innovative and ergonomic, these interchangeable measurement modules allow an easy evolution of your instrument functions.
Calibration certificate supplied with each module guarantees accurate and reliable datasets ans is time-saving for pool-maintenance

Pressure Measurement Module
Measurement module with2 pressure inputs and 1 thermocouple input

Pressure:
from -500to +500 Pa
from -2500to +2500 Pa
from -10000to +10000 Pa
from -500to +500 mbar
from -2000to +2000 mbar
Temperature : K, J or T thermocoupleinputs


Temperature Measurement Module
Measurement modules with 4 thermocouple temperature inputs
Thermocouple K :from -200to +1300°C
ThermocoupleJ :from -100to +750°C
ThermocoupleT :from -200to +400°C


Current / Voltage Measurement Module
Measurement module with 2 current or voltage inputs
Current :from 0to 4-20 mA
Voltage:from 0to 10 V

   ● Accessories  

 

Current / Voltage Input Cables

PVC cable, length 2 m. Measuring range :
-from 0to 2500 mV
-from 0to 10 V
-from 0to 4/20 mA


Ammeter Clamps
Accuracy: 1% of the scale.
Available measurement ranges: 0-20A, 0-50A, 0-100A, 0-200A, 0-600A.

Pitot Tubes
Accuracy : more than 0,5 % for an alignment with to the fluid axis flow within 12°
Pitot tubes conform to AFNOR.NF.X10.112.norm. Appendix 4 dated 14.9.77.
Type : ellipsoidal head curved NPL
Coefficient : 1,0015.
Quality : Hard stainless steel; 4/4 to AFNOR / Z2.CND.17.12.

Debimo
KIMO DEBIMO flow measuring blades are a simple and cost effective method of providing permanent air flow measurement in rectangular or circular ducts.
When used with a KIMO differential pressure device (pressure, transmitter, electronic micromanometer, liquid column manometer, differential pressure switch, ...).
DEBIMO air flow measuring blades ensure accurate indication, control or recording of air flow velocity and volume

Telescopic Extension
Telescopic bent extension to 90°
Length 1 m, compatible with all measurement probes.

Data Logger-10

Datalogger-10 operating system for portable instruments. Wire (LPCF)or wireless (LPCR)interface.